OMRON - 3G3MX2-V1

OMRON - 3G3MX2-V1

Delts - DOP-B07S411

Features :


High starting torque and torque control capability in open loop mode give you full control of your machine dynamics and performance. Options for all of the major open network systems.

Function Specifications :

Function name

Specifications

Enclosure ratings *1

Open type (IP20)

Control Control method

Phase-to-phase sinusoidal modulation PWM

Output frequency range 
*2

0.10 to 400 Hz (or 580 Hz in the high-frequency mode; restrictions apply)

Frequency precision *3

Digital command: ±0.01% of the max. frequency, Analog command: ±0.2% of 
the max. frequency (25±10 °C)

Frequency setting 
resolution

Digital setting: 0.01 Hz, Analog setting: One-thousandth of the maximum 
frequency

Voltage/Frequency 
characteristics

V/f characteristics (constant/reduced torque) 
Sensorless vector control, V/f control with speed feedback

Overload current rating

Heavy load rating (CT): 150%/60 s 
Light load rating (VT): 120%/60 s

Instantaneous 
overcurrent protection

200% of the value of heavy load rating (CT)

Acceleration/ 
Deceleration time

0.01 to 3600 s (linear/curve selection), acceleration/deceleration 2 setting 
vailable

Carrier frequency 
adjustment range

2 to 15 kHz (with derating)

Starting torque

200%/0.5 Hz (sensorless vector control)

External DC injection 
braking

Starts at a frequency lower than that in deceleration via the STOP command, 
at a value set lower than that during operation, or via an external input. (Level 
and time settable).

Protective functions

Overcurrent, overvoltage, undervoltage, electronic thermal, temperature 
error, ground fault overcurrent at power-on status, rush current prevention 
circuit, overload limit, incoming overvoltage, external trip, memory error, CPU 
error, USP error, communication error, overvoltage suppression during 
deceleration, protection upon momentary power outage, emergency cutoff, etc.

Input 
signal
Frequency settings

Digital Operator 
External analog input signal: 0 to 10 VDC/4 to 20 mA, Modbus communication 
(Modbus-RTU)

RUN/STOP command

Digital Operator 
External digital input signal (3-wire input supported), Modbus communication 
(Modbus-RTU)

Multi-function input

7 points (Selectable from 59 functions)

Analog input

2 points (Voltage FV terminal: 10 bits/0 to 10 V, Current FI terminal: 10 bits/4 
to 20 mA)

Pulse input

1 point (RP terminal: 32 kHz max., 5 to 24 VDC)

Output 
signal
Multi-function output

2 points (P1/EDM, P2; selectable from 43 functions)

Relay output

1 point (1c contact: MC, MA, MB; selectable from 43 functions)

Analog output 
(Frequency monitor)

1 point (AM terminal: Voltage 10 bits/0 to 10 V) (Frequency, current selectable)

Pulse output

1 point (MP terminal: 32 kHz max., 0 to 10 V)

Communi-
cations
RS-422

RJ45 connector (for Digital Operator)

RS-485

Control circuit terminal block, Modbus communication (Modbus-RTU)

USB

USB1.1, mini-B connector

Drive Programming *4

Calculate, Logic, Control I/O and so on

Other functions

AVR function, V/f characteristics switching, upper/lower limit, 16-step 
speeds, starting frequency adjustment, jogging operation, carrier frequency 
adjustment, PID control, frequency jump, analog gain/bias adjustment, S shape 
acceleration/deceleration, electronic thermal characteristics, level 
adjustment, restart function, torque boost function, fault monitor, soft lock 
function, frequency conversion display, USP function, motor 2 control function, 
UP/DWN, overcurrent control function, etc.

Operating 
environ- 
ment
Ambient operating 
temperature

-10 to 50 °C (However, derating is required).

Ambient storage 
temperature

-20 °C to 65 °C

Ambient operating 
humidity

20% to 90% RH (with no condensation)

Vibration resistance

5.9 m/s2 (0.6G), 10 to 55 Hz

Application 
environment

At a maximum altitude of 1,000 m; indoors (without corrosive gases or dust)

Options EtherCAT 
Communication Unit

3G3AX-MX2-ECT

CompoNet 
Communication Unit

3G3AX-MX2-CRT-E

DeviceNet 
Communication Unit

3G3AX-MX2-DRT-E

Other option

DC reactor, AC reactor, radio noise filter, input noise filter, output noise filter,  regenerative braking unit, Braking Resistor, etc.

Interna- 
tional 
standard
EC di- 
rective
EMC directive

EN61800-3: 2004

Low voltage 
directive

EN61800-5-1: 2007

Machinery 
directives

IEC 60204-1 Stop Category 0, EN IEC 61800-5-2 (STO), EN ISO 13849-1: 2008 
(PLd)

UL/cUL

UL508C


  • Protection method complies with JEM 1030.
  • To operate the motor at over 50/60 Hz, contact the motor manufacturer to find out the maximum allowable speed of revolution.
  • For the stable control of the motor, the output frequency may exceed the maximum frequency set in A004 (A204) by 2 Hz max.
  • 4 Refer to the Drive Programming USER'S MANUAL (No. I580).

Notes :

  • The applicable motor is a 3-phase standard motor. For using any other type, be sure that the rated current does not exceed that of the Inverter.
  • Output voltage decreases according to the level of the power supply voltage.
  • The braking torque at the time of capacitor feedback is an average deceleration torque at the shortest deceleration (when it stops from 50 Hz). It is not a continuous regeneration torque. Also, the average deceleration torque varies depending on the motor loss. The value is reduced in operation over 50 Hz.